Electric Thermal Oil Boiler:
Future electric thermal oil boiler (also known as heat conduction oil heater), the electric oil boiler is directly inserted into the organic carrier (heat conduction oil) for direct heating. A circulating pump is used to create liquid-phase circulation of heat conduction oil, thus, to transfer the heat to one or several pieces of heat using equipment. After unloaded in the heat using equipment, the heat conduction oil will return to the heater via the circulating pump, again to absorb heat, and transfer the heat to the heat using equipment. This process is repeated again and again, realizing continuous transfer of heat. As a result, the temperature of objects being heated rises, and heating requirements are fulfilled.
1. Characteristics:
1. Low Operating Pressure
Liquid phase heat transfer can reach a higher operating temperature under lower operating pressure; Saturated vapor pressure of heat carrier is 70 to 80 times lower than that of water; And its general operating pressure is 0.3MPa.
2. High Heating Temperature
Heating temperature of the electric heat conduction oil furnace may reach 320; Heating-up temperature is automatically controlled, realizing high sensitivity and stable heat supply.
3. Safe and Reliable
Our electric heat conduction oil furnace is equipped with a perfect operating control and safety monitoring device, so it is easy to operate, safe, and reliable.
4. Environmental Friendly Design
The electric heat conduction oil furnace is a new type of electric heating system. Electricity is used instead of coal, which reduces investment outlay and is free from contamination; Meanwhile, heat conduction oil furnace, with short heating time and high thermal efficiency, is more efficient and economical!
2. Technical Parameters:
Model Parameters | YGW-24D | YGW-48D | YGW-72D | YGW-120D | YGW-150D | YGW-180D | YGW-240D | YGW-360D | YGW-500D | YGW-600D | YGW-720D |
Heat Power KW | 24 | 48 | 72 | 120 | 168 | 180 | 240 | 360 | 504 | 600 | 720 |
Design Pressure Mpa | 0.6 | 0.6 | 0.6 | 0.68 | 0.68 | 0.68 | 0.7 | 0.7 | 0.7 | 0.7 | 0.7 |
Max. Working Temp. °C | 320 | 320 | 320 | 320 | 320 | 320 | 320 | 320 | 320 | 320 | 320 |
Oil Capacity in Furnace M3 | 0.02 | 0.03 | 0.05 | 0.08 | 0.11 | 0.12 | 0.15 | 0.25 | 0.4 | 0.5 | 0.6 |
Thermal Efficiency % | 90% | 90% | 90% | 90% | 90% | 90% | 90% | 90% | 90% | 90% | 90% |
Oil Recyle Capacity M3/h | 8 | 8 | 12.5 | 12.5 | 32 | 32 | 40 | 40 | 60 | 80 | 80 |
Dia. of pipe connection | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 80 | 80 | 100 | 100 |
System Power KW | 28 | 58 | 90 | 150 | 180 | 210 | 280 | 400 | 560 | 670 | 810 |
Overall Dimension | Length mm | 1800 | 1800 | 1800 | 2000 | 2000 | 2000 | 2000 | 2000 | 2390 | 2390 | 2390 |
Width mm | 600 | 600 | 850 | 1350 | 1350 | 1700 | 1800 | 2200 | 1506 | 1506 | 1986 |
Height mm | 1600 | 1850 | 1850 | 1650 | 2200 | 1650 | 1650 | 2000 | 1865 | 1865 | 1865 |
Net Weight Kg | 540 | 660 | 780 | 1085 | 1240 | 1300 | 1400 | 2300 | 3800 | 4260 | 4680 |
3. Main Parts of Heater: