CE Certification Gas Steam Boiler:
I. Detailed Product Description:
1) WNS series full automatic gas(oil) steam boilers adopt heat components of the structure of horizontal three-pass wet back as corrugated smoke tube. Adopting wetback down stream structure,which can avoid the problems that the smoke box of the dryback and central backflash system could be sealed and the temperature of the smoke box could be too high.
2) The inner furnace adopts the most advanced structure-corrugated furnace, which can increase the heat transfer area and the stability of the furnace.
3) The smoke tube adopts high efficient heat transfer component—threaded smoke tube. It raises the heat transfer coefficient of the smoke tube. The volume of the boiler can be further decreased.
4) The entire boiler installed in the steel base. If the FD fan needs to be installed separately, then use the flexible joint at the interface of combustion chamber and the blower duct. Steel base using fixed angle expansion bolts.
5) Boiler is using two-way full-opening and big-open furnace door design. The internal structure of the furnace is clear and repair to maintain. Observation window installed at both ends of the boiler, install hand-holes in order to check and clean the boiler. Install lifting rings at the top of the boiler shell installed front and rear hinges, gaskets and insulation.
NOTE: CE marking as per Pressure Equipment Directive (PED 97/23/EC) as options, and ASME Code is available.
Technical Parameters:
Model | WNS5-1.25-Y.Q | WNS6-1.25-Y.Q | WNS8 -1.0-Y.Q | WNS10-1.25-Y.Q | WNS12-1.25-Y.Q | WNS15-1.25-Y.Q |
Item | Unit |
Steam Capacity | t/h | 5 | 6 | 8 | 10 | 12 | 15 |
Utilization Horsepower | BHP | 320 | 384 | 512 | 640 | 768 | 960 |
Equivalent Output | lbs/h | 11000 | 13200 | 17600 | 22000 | 26400 | 33000 |
Rated Working Pressure | MPa | 1.25 (1.6, 2.5) |
Saturated Steam Temp. | °C | 193 (204, 224) |
Heating Surface | m2 | 163.1 | 181.17 | 190.77 | 232.16 | 346.3 | 467.5 |
Fuel Consumption | Light Diesel | Kg/h | 340 | 408 | 540 | 680 | 810 | 1020 |
Heavy Oil | Kg/h | 348.4 | 418.1 | 553 | 707 | 836 | 1044.9 |
Natural Gas | Nm3/h | 370 | 440 | 592 | 740 | 886 | 1110 |
LPG | Nm3/h | 130 | 156 | 226 | 260 | 310 | 390 |
Water Inlet Dia. | DN | 40 | 40 | 50 | 50 | 50 | 50 |
Main Steam Outlet Dia. | DN | 125 | 125 | 150 | 150 | 200 | 200 |
Safety Valve Dia. | DN | 80/50 | 80/50 | 2×80 | 2×80 | 2×100 | 2×100 |
Blowdown Valve Dia. | DN | 2×50 | 2×50 | 2×50 | 2×50 | 3×50 | 3×50 |
Overall Dimension | mm | 6730×2900×3600 | 7200×3260×3900 | 7500×3680×4100 | 8100×3800×4200 | 8200×3800×4600 | 8700×4050×4800 |
Net Weight | Kg | 14300 | 19500 | 22600 | 25800 | 32700 | 40500 |
Details:
1. Customer's Using Site:
2. Boiler Body & Production:
3. Package & Delivery of Boiler: